<LOGO>
FM Transmitter Measurement Report
Created: 2025-09-12 07-16-14
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
101.90 MHz 5/5, 40 dBuV R-PLUS
Pilot RDS Phase Difference
0.0 kHz 3.7 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 2,0 kHz
MIN Hold Max. Samples at Total Samples % above 77,0 kHz
6 kHz 49 kHz 17839 0,0897
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-0,6 dBr -0,04 dBr 0,4 dBr 5,7
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"R-PLUS " 2424 2 (Affairs) 1 0 0 0 7:16, 12.09.2025
RT
"Cesky rozhlas Plus - kdyz chcete vedet proc "
AF EON
91.3, 91.5, 92.6, 92.8, 93.3, 93.5, 93.9, 94.1, 95.4, 97.8, 100.8, 101.5, 101.9, 103.6, 107.2 MHz -
FM Scope Max at: 49 kHz MIN: 6 kHz % above 77 kHz: 0,0897 Acquired: 2025/09/12 7:16:11 Total samples: 17839 Equivalent time: 0:14:51 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 100 200 300 400
FM Scope MAX: 0,4 dBr MIN: -0,6 dBr AVE: -0,04 dBr % above 0,2 dBr: 5,7 Last value: 0,0 dBr (2025/09/12 7:16:10) 07:02 07:04 07:06 07:08 07:10 07:12 07:14 07:16 -4 -2 0 2 4 Pm [dBr] 0 5 Signal Quality